netcore
25m (82ft) MTP® Trunk Cable, MTP®-8 UPC (Female) to MTP®-8 UPC (Female), 8 Fibers, Multimode (OM4), Plenum (OFNP), 0.20dB Max, Type B, Double Jacket
1 / 4
Fiber Optic Cables · 8FMTPOM4

25m (82ft) MTP® Trunk Cable, MTP®-8 UPC (Female) to MTP®-8 UPC (Female), 8 Fibers, Multimode (OM4), Plenum (OFNP), 0.20dB Max, Type B, Double Jacket

25m (82ft) MTP® Trunk Cable, MTP®-8 UPC (Female) to MTP®-8 UPC (Female), 8 Fibers, Multimode (OM4), Plenum (OFNP), 0.20dB Max, Type B, Double Jacket, Magenta, Product Specification:Connector A - US Conec MTP® Elite Female (Non-Pinned), Connector B - US Conec MTP® Elite Female (Non-Pinned), Fiber Mode - OM4 50/125μm, Wavelength - 850/1300nm, Glass Fiber - Bend Insensitive Fiber, Minimum Bend Radius - 7.5mm

Net price · DE
€157,00
ex. VAT
In stock
1-year warranty · Netcore-backed

MTP®-8 Trunk Cable, F to F, UPC, 8F, OM4, OFNP, 0.20dB, Type B

MTP® trunks are factory pre-terminated and rigorously tested, coming with reliable MTP®-MTP® or MTP®-LC Uniboot connectors. Ultra-low loss MTP® connectors can reduce signal loss during transmission to support long-distance transmissions and multiple connection areas. The robust double-jacket sheath enhances crush resistance, ensuring durability and performance over long-distance runs. These features make MTP® trunks an ideal choice for high-density cabling in data centres, widely used in main, horizontal, and zone distribution areas.

Highlights

Specifications

22 fields
Connector AUS Conec MTP® Elite Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Glass FiberBend Insensitive Fiber
Minimum Bend Radius7.5mm
Polish TypeUPC to UPC
PolarityType B
Cable JacketPlenum (OFNP)
Cable StructureDouble Jacket
Fiber Count8 Fibers (Base-8)
Breakout Length0.84m
Cable Outside Diametre (OD)3.6-4.5mm
Breakout Outside Diametre (OD)2.0mm
Insertion Loss ≤0.20dB
Return Loss≥27dB
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Long-term Tensile Load <br/>100N
Short-term Tensile Load <br/>300N
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-10 to +70°C (14 to 158℉) <br/>

Features

Double Jacket Sheath Protects Network Connection Further

Double jacket with greater crush resistance protects the fibre optic core and increases the strength and durability of the fibre.

Superior Workmanship Guarantees Stable Transmission

MTP® cables are offering state-of-the-art multi-fibre and mechanical performance.

Plenum Jacket, The Highest Fire Safety-Rated

Color-Coded Connector Boots for Easy Identification

Color-coded boots can prevent improper mating and reduce installation confusion during moves, additions, or changes, improving cabling efficiency.

High Density Cabling for Various Environments

Clean Fiber Means Performance

Visual Cable Management with FSWireNet

Datasheets & documents